Turbosmart WASTEGATES – EXTERNAL - Comp-Gate40 (with locking Bedienungsanleitung Seite 8

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 9
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 7
www.TURBOSMARTONLINE.com
8
Two port connection Method (2) (For obtaining maximum boost pressure on your turbo system)
Port 1 of solenoid to Top port of wastegate
Port 2 of solenoid to Pressure only source
Port 3 of solenoid to Bottom port of wastegate
Two port connection Method (3) (For obtaining a wide range of boost pressures e.g. 5 – 40 PSI, note that this method of boost control
may not provide a smooth boost curve)
Port A of solenoid to Top port of wastegate
Port B of solenoid to Bottom port of wastegate
EX port of solenoid vent to atmosphere
IN port of solenoid to Pressure only source
4 Port solenoid
EX Port of solenoid vent
to atmosphere
IN Port of solenoid to
pressure only source
Turbocharger
Port A of solenoid to top port of
wastegate
Wastegate
Port B of solenoid to
bottom port of wastegate
Turbocharger
Port 2 of solenoid to
pressure only source
Solenoid
Port 1 of solenoid to
Top port of wastegate
Port 3 of solenoid to
bottom port of wastegate
Wastegate
Seitenansicht 7
1 2 3 4 5 6 7 8 9

Kommentare zu diesen Handbüchern

Keine Kommentare